Skip to content
GreenOps

Kubernetes CO₂e per workload, cluster and region.

Estimated from CPU, memory and GPU energy, provider PUE, and each region’s grid carbon intensity (Ember 2024). Monthly and quarterly CSV export.

Where you run

The same workload can emit 89× more CO₂e, depending on region.

Grid intensity runs from 8 g/kWh in eu-north-1 to 708 g/kWh in ap-south-1.

8g/kWh

eu-north-1

Sweden · hydro

130g/kWh

ca-central-1

Quebec · hydro

316g/kWh

eu-west-1

Ireland

322g/kWh

us-east-1

Virginia

442g/kWh

Global avg

Mixed grid

708g/kWh

ap-south-1

Mumbai · coal-heavy

0 g/kWh5001000 g/kWh

Same workload, up to 89× the emissions. Region matters.

Source · Ember Climate · Global Electricity Review 2024

Method

What we count, and what we leave out.

Every figure is an estimate from a published model: CCF, SPECpower and Ember 2024.

Counted

4 components
  • CPU compute energy

    SPECpower curves, per processor family

  • Memory energy

    0.3725 W per GiB, DDR4 baseline

  • GPU compute energy

    TDP per model, utilization-weighted

  • Data-centre overhead

    Provider PUE, which includes cooling and facility networking

Excluded

4 domains
  • Network transfer energy

    Energy of moving data between sites

  • Embodied carbon

    Manufacturing footprint of hardware

  • Storage device energy

    Provider-side, not exposed by APIs

  • End-user device energy

    Outside the data center boundary

Following the SCI specification and the Cloud Carbon Footprint methodology.

  • CCF
  • SPECpower
  • Ember 2024
  • Provider PUE
  • SCI (ISO/IEC 21031:2024)

Reports

Monthly and quarterly CO₂e, exported as CSV.

CO₂e by cluster for the month or quarter. The methodology and constants are published.

Example · GreenOps report

Q2 2026

ClustertCO₂eChange
  • prod-eu-11.42-8.1%
  • prod-us-east2.18+4.4%
  • staging-eu0.31-12.0%
TOTAL3.91-1.9%

Data sources: CCF, SPECpower, Ember 2024, provider PUE, SCI

Boundary: CPU, memory and GPU energy, plus data-centre overhead via provider PUE. Excludes network transfer, storage devices and embodied carbon.

Format: CSV, monthly or quarterly. Figures are estimates.

The report includes

  • Per-cluster breakdown

    tCO₂e for each cluster in the period

  • Change over time

    Each cluster against the previous period

  • Published methodology

    CCF, SPECpower, Ember 2024, provider PUE and SCI: formulas and constants

Install in 5 minutes

Stop paying for unused capacity.

Free up to 100 vCPU. After that, $1.99 per vCPU per month, dropping to $0.60 at volume.

Agent runs in your clusterNo credit card